StructureCalcs

400WC144

Welded Column · AS/NZS 3679.2 · Australia / New Zealand

400WC144 is a welded column 382.0 mm deep with a 400.0 mm wide flange, weighing 144.4 kg/m. The dimensions below are the published AS/NZS 3679.2 values; the drawing is generated from them.

Welded Columns extend the UC range the same way — three-plate sections for heavy column and transfer applications.

400WC144 drawn to scale. Save as SVG DXF

Analyse this section, or combine it with plates and other shapes.

Open 400WC144 in the Section Calculator

Free, no sign-up, runs in your browser.

Published dimensions

PropertyMetricImperial
Depth, d382.0 mm15.04 in
Flange width, bf400.0 mm15.75 in
Flange thickness, tf16.0 mm0.630 in
Web thickness, tw16.0 mm0.630 in
Mass per metre144.4 kg/m97.1 lb/ft
Area, A18,400 mm²28.52 in²
Second moment, Ix486,098,933 mm⁴1,167.9 in⁴
Second moment, Iy171,000,000 mm⁴410.8 in⁴

Derived section properties

Integrated from the section's exact plate outline — a welded section has square corners by construction, so nothing is approximated. For 400WC144 the computed area agrees to better than 0.01% and Ix to better than 0.01%. Where a value is also published, the published one above is the one to quote.

PropertyValue
Elastic modulus, Zx2,545,021 mm³
Elastic modulus, Zy853,931 mm³
Plastic modulus, Sx2,832,400 mm³
Plastic modulus, Sy1,302,400 mm³
Radius of gyration, rx162.5 mm
Radius of gyration, ry96.3 mm

Z is the elastic modulus and S the plastic modulus, following AS 4100. Under AISC 360 the letters are reversed.

Neighbouring sizes

Where these numbers come from

Published AS/NZS 3679.2 values. How StructureCalcs verifies its numbers · Understanding steel section properties · Query this section over the API