StructureCalcs

65 x 50 x 5 UA

Unequal Angle · AS/NZS 3679.1 · Australia / New Zealand

65 x 50 x 5 UA is an unequal angle with 65 × 50 mm legs, 4.6 mm thick, weighing 4.0 kg/m. The dimensions below are the published AS/NZS 3679.1 values; the drawing is generated from them.

Unequal Angles put the longer leg where connection or stiffness demands it; like every angle they buckle about tilted principal axes, and the principal pair is published here.

65 x 50 x 5 UA drawn to scale. Save as SVG DXF

Analyse this section, or combine it with plates and other shapes.

Open 65 x 50 x 5 UA in the Section Calculator

Free, no sign-up, runs in your browser.

Published dimensions

PropertyMetricImperial
Leg length, d65 mm2.56 in
Second leg, b50 mm1.97 in
Thickness, t4.6 mm0.181 in
Mass per metre4.0 kg/m2.7 lb/ft
Area, A512 mm²0.79 in²
Second moment, Ix214,900 mm⁴0.5 in⁴
Second moment, Iy110,800 mm⁴0.3 in⁴
Principal maximum, Imax267,000 mm⁴0.6 in⁴
Principal minimum, Imin58,700 mm⁴0.1 in⁴

Derived section properties

Integrated from the section's own outline including the root and toe radii, whose arcs are integrated analytically rather than approximated by facets. For 65 x 50 x 5 UA the computed area agrees with the published value to 0.06% and Ix to 0.05%. Where a value is also published, the published one above is the one to quote.

PropertyValue
Elastic modulus, Zx4,753 mm³
Elastic modulus, Zy2,945 mm³
Plastic modulus, Sx8,705 mm³
Plastic modulus, Sy5,324 mm³
Radius of gyration, rx20.5 mm
Radius of gyration, ry14.7 mm
Principal maximum, Imax (derived)267,124 mm⁴
Principal minimum, Imin (derived)58,698 mm⁴
Principal axis angle, θp30.0°

Z is the elastic modulus and S the plastic modulus, following AS 4100. Under AISC 360 the letters are reversed.

Neighbouring sizes

Where these numbers come from

Published AS/NZS 3679.1 values. How StructureCalcs verifies its numbers · Understanding steel section properties · Query this section over the API