StructureCalcs

100 x 75 x 10 UA

UA · AS/NZS 3679.1 · Australia / New Zealand

100 x 75 x 10 UA is a ua 100.0 mm deep with a 75.0 mm flange, weighing 12.4 kg/m. The dimensions below are the published AS/NZS 3679.1 values; the drawing is generated from them.

100 x 75 x 10 UA drawn to scale. Save as SVG

Analyse this section, or combine it with plates and other shapes.

Open 100 x 75 x 10 UA in the Section Calculator

Free, no sign-up, runs in your browser.

Published dimensions

PropertyMetricImperial
Depth, d100.0 mm3.94 in
Flange width, bf75.0 mm2.95 in
Flange thickness, tf— mm— in
Web thickness, tw9.5 mm0.374 in
Mass per metre12.4 kg/m8.3 lb/ft
Area, A1,580 mm²2.45 in²
Second moment, Ix1,547,000 mm⁴3.7 in⁴
Second moment, Iy744,000 mm⁴1.8 in⁴
Principal maximum, Imax1,890,000 mm⁴4.5 in⁴
Principal minimum, Imin401,000 mm⁴1.0 in⁴

Derived section properties

Integrated from the section's own outline including the root and toe radii, whose arcs are integrated analytically rather than approximated by facets. For 100 x 75 x 10 UA the computed area agrees with the published value to 0.30% and Ix to 0.13%. Where a value is also published, the published one above is the one to quote.

PropertyValue
Elastic modulus, Zx22,642 mm³
Elastic modulus, Zy13,352 mm³
Plastic modulus, Sx41,309 mm³
Plastic modulus, Sy24,310 mm³
Radius of gyration, rx31.3 mm
Radius of gyration, ry21.7 mm
Principal maximum, Imax (derived)1,886,405 mm⁴
Principal minimum, Imin (derived)401,377 mm⁴
Principal axis angle, θp28.6°

Z is the elastic modulus and S the plastic modulus, following AS 4100. Under AISC 360 the letters are reversed — S is elastic and Z is plastic.

Neighbouring sizes

Where these numbers come from

Published AS/NZS 3679.1 values. How StructureCalcs verifies its numbers · Understanding steel section properties · Query this section over the API