StructureCalcs

125 x 75 x 10 UA

UA · AS/NZS 3679.1 · Australia / New Zealand

125 x 75 x 10 UA is a ua 125.0 mm deep with a 75.0 mm flange, weighing 14.2 kg/m. The dimensions below are the published AS/NZS 3679.1 values; the drawing is generated from them.

125 x 75 x 10 UA drawn to scale. Save as SVG

Analyse this section, or combine it with plates and other shapes.

Open 125 x 75 x 10 UA in the Section Calculator

Free, no sign-up, runs in your browser.

Published dimensions

PropertyMetricImperial
Depth, d125.0 mm4.92 in
Flange width, bf75.0 mm2.95 in
Flange thickness, tf— mm— in
Web thickness, tw9.5 mm0.374 in
Mass per metre14.2 kg/m9.5 lb/ft
Area, A1,810 mm²2.81 in²
Second moment, Ix2,887,000 mm⁴6.9 in⁴
Second moment, Iy789,000 mm⁴1.9 in⁴
Principal maximum, Imax3,200,000 mm⁴7.7 in⁴
Principal minimum, Imin476,000 mm⁴1.1 in⁴

Derived section properties

Integrated from the section's own outline including the root and toe radii, whose arcs are integrated analytically rather than approximated by facets. For 125 x 75 x 10 UA the computed area agrees with the published value to 0.15% and Ix to 0.10%. Where a value is also published, the published one above is the one to quote.

PropertyValue
Elastic modulus, Zx34,861 mm³
Elastic modulus, Zy13,705 mm³
Plastic modulus, Sx62,484 mm³
Plastic modulus, Sy25,071 mm³
Radius of gyration, rx39.9 mm
Radius of gyration, ry20.9 mm
Principal maximum, Imax (derived)3,196,537 mm⁴
Principal minimum, Imin (derived)476,293 mm⁴
Principal axis angle, θp19.8°

Z is the elastic modulus and S the plastic modulus, following AS 4100. Under AISC 360 the letters are reversed — S is elastic and Z is plastic.

Neighbouring sizes

Where these numbers come from

Published AS/NZS 3679.1 values. How StructureCalcs verifies its numbers · Understanding steel section properties · Query this section over the API