125 x 75 x 12 UA
UA · AS/NZS 3679.1 · Australia / New Zealand
125 x 75 x 12 UA is a ua 125.0 mm deep with a 75.0 mm flange, weighing 17.7 kg/m. The dimensions below are the published AS/NZS 3679.1 values; the drawing is generated from them.
Analyse this section, or combine it with plates and other shapes.
Open 125 x 75 x 12 UA in the Section CalculatorFree, no sign-up, runs in your browser.
Published dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 125.0 mm | 4.92 in |
| Flange width, bf | 75.0 mm | 2.95 in |
| Flange thickness, tf | — mm | — in |
| Web thickness, tw | 12.0 mm | 0.472 in |
| Mass per metre | 17.7 kg/m | 11.9 lb/ft |
| Area, A | 2,260 mm² | 3.50 in² |
| Second moment, Ix | 3,537,000 mm⁴ | 8.5 in⁴ |
| Second moment, Iy | 958,000 mm⁴ | 2.3 in⁴ |
| Principal maximum, Imax | 3,910,000 mm⁴ | 9.4 in⁴ |
| Principal minimum, Imin | 585,000 mm⁴ | 1.4 in⁴ |
Derived section properties
Integrated from the section's own outline including the root and toe radii, whose arcs are integrated analytically rather than approximated by facets. For 125 x 75 x 12 UA the computed area agrees with the published value to 0.04% and Ix to 0.04%. Where a value is also published, the published one above is the one to quote.
| Property | Value |
|---|---|
| Elastic modulus, Zx | 43,296 mm³ |
| Elastic modulus, Zy | 16,941 mm³ |
| Plastic modulus, Sx | 77,308 mm³ |
| Plastic modulus, Sy | 31,414 mm³ |
| Radius of gyration, rx | 39.6 mm |
| Radius of gyration, ry | 20.6 mm |
| Principal maximum, Imax (derived) | 3,911,883 mm⁴ |
| Principal minimum, Imin (derived) | 585,064 mm⁴ |
| Principal axis angle, θp | 19.6° |
Z is the elastic modulus and S the plastic modulus, following AS 4100. Under AISC 360 the letters are reversed — S is elastic and Z is plastic.
Neighbouring sizes
Where these numbers come from
Published AS/NZS 3679.1 values. How StructureCalcs verifies its numbers · Understanding steel section properties · Query this section over the API